VCR, a leading authority in cleanroom equipment, brings you an expert exploration.

Types of Pass Box Accessories

1. Static Pass Box Accessories:

static pass box accessories
Static Pass Box Accessories
  • Mechanical/Electronic Interlock System
  • Rubber Edge Trim
  • Wires and Socket
  • Door Handle
  • UV Lamp/Lamp
  • Hinge

2. Dynamic Pass Box Accessories:

Dynamic Pass Box Accessories
Dynamic Pass Box Accessories

In addition to static accessories, dynamic pass boxes include:

  • Pre-filter
  • HEPA Filter
  • Differential Pressure Gauge
  • Motor Blower
  • DOP/PAO Test Port

Details on Key Accessories

1. Passbox Interlock System:

  • Ensures doors don't open simultaneously, reducing cross-contamination risks.
  • Mechanical system features internal interlock and sturdy external handle.
  • Electronic system uses built-in circuits with indicator lights for door status.

2. Door Handle:

  • Installed in electronic interlock system pass boxes.
  • Not required in mechanical interlock systems, as interlock serves as the handle.

3. UV Lamp:

  • Germicidal UV light enhances protection.
  • Destroys DNA pathogens with short-wave ultraviolet radiation.
Pass Box cleanroom
Dynamic Pass Box

4. Hinge:

Stainless steel hinge is dust-free and easy to clean.

5. Rubber Edge Trim:

Door seals with rubber edge trim facilitate easy cleaning.

6. Pre-filter:

  • Removes larger particles, extending the life of HEPA filters.
  • Regular checks and replacement every one to six months recommended.

7. HEPA Filter:

  • Filters particles of 0.3µm or larger, providing filtered and fresh air in cleanrooms.
  • Replace following manufacturer's guidelines or at least every six months.

8. Differential Pressure Gauge:

  • Monitors pressure across HEPA filter.
  • Dynamic pass box gauges: 0-250 Pa and 0-500 Pa.

9. DOP/PAO Test Port:

Facilitates HEPA filter leak tests and particle count assessments.

See more: Pass box specifications

Usage Precautions

Dynamic Pass Box And Static Pass Box
Dynamic Pass Box And Static Pass Box

1. Interlock System:

Ensure doors are not open simultaneously during transfer.

2. UV Lamp:

  • Close both doors before activating.
  • Avoid direct hand contact.
  • Replace lamp every 4000 hours following guidelines.

3. Pre-filter:

Check, clean, and replace every one to six months.

4. HEPA Filter:

Change according to manufacturer's instructions or at least every six months.

5. Differential Pressure Gauge:

Utilize gauges specific to dynamic pass boxes.

See more: 9 Considerations For Dynamic Pass Box

Conclusion:

This detailed guide on pass box accessories and their proper use aims to address your concerns. For replacement accessories or further inquiries, contact VCR - Vietnam Cleanroom Equipment at hotline 090 123 7008. Elevate your cleanroom standards with precision-engineered accessories.